Concept
The renovation of the Main building aimed to create a showpiece building which shows innovation, sustainability and technology. A new volume is added towards the West to make itself visible from the entrance of the campus (See Atrium concept).
The Atrium contributes to the design as a visual space, circulation, and daylight provided by its skylight roof. In order to avoid overheating during summer, external shadings are located in the roof, to be automatized during peak hours (See View of the atrium).
The “Old” building façade towards East and West has external rotating louvers made out of perforated aluminum, in order to provide natural light to the interior space even when the louvers are closed, avoiding the unwanted solar gains. The “New” building has a double skin façade with external vents in order to provide air flow to the new cavity. The mechanism of this façade differs depending on the season.


Building Physics
The concept of the building not only creates an interaction space among the users but also provides a high quality indoor environment. The daylight system is the most important aspect in the design. As part as the daylight system light shelves are located in the east façade and louvers with daylight redirection on the west façade. A daylight sensor turns on the artificial LED lights depending on light admittance.



1. Rotating Louver (Perforated aluminium)
2. Internal Shading
3. Operable window
4. Radiant panel (Ventilation, cooling and heating)
5. Supply duct
6. Return grille
7. Ceiling plenum (insulated)
8. Floor difusser (Personal control)
9. Floor pressurised plenum
10. LED lighting (Daylight sensor
11. Light shelf
12. Perimeter Convector (Cooling and heating)
Fifht Floor
Sixth Floor

1. 50 mm layer of Gravel
Polymer-bitumen roof sealing layer
40 mm EPS hard insulation board
60 mm Morter layer
110 mm EPS hard insulation board
Vapor Barrier
Concrete slab (Existing)
U-value = 0,20 W/m2K
2. Aluminum parapet
3. 110mm Precast concrete panel
Rockwoll insulation
Vapor Barrier
3mm Aluminum sheet
Uvalue = 0,25 W/m2K
4. Rotating mechanism with motor
5. 30mm raised panel floor system
510 mm Pressurized plenum
50 mm EPS hard insulation board
Vapor Barrier
Concrete Slab (Existing)
Uvalue = 0.38 W/m2K
6. Internal Blind
7. 350 mm Pressurized plenum for return air
30 mm EPS hard insulation board
10 mm plaster ceiling board
Uvalue = 0.67 W/m2K
8. Double Glazing Window
Insulated Frame
Uvalue = 1,16 W/m2K
Detail Facade with Louvers
MASTER THESIS
Towards Net Zero
Renovation of the "Hoofdgebouw"